Chapter:
Design-of-sewers-Tutorial
A 60 cm diameter sewer is to discharge `0.07` `m^3`/sec at a velocity as self cleansing as sewer flowing full at 0.85 m/sec. Find depth and velocity of flow and required slope. Take uniform value of manningā??s coefficients (n) = 0.015
Solution:
When sewer is running full,
`d=0.6\ m`
`v=0.85=1/0.015(d/4)^(2/3)**(S)^(1/2)`
or, `S=1/490.269` and the discharge is,
`Q=pi**0.6^2/4**0.85=0.24\ m^3/s`
For partial depth self cleansing flow
`q_s=0.07\ m^3/s`
or, `q_s/Q=0.07/0.24=0.2912`
or, `0.2912=(theta/360-(sin theta)/(2pi))(1-(360 sin theta)/(2 pi theta))^(1/6)`
or, `theta=143.63^0`
Also, we have,
`d/D=1/2(1-cos theta/2)=0.3439`
or, `d=0.2063\ m`
Also,
`r/R=(1-(260 sin theta)/(2 pi theta))`
`=0.763`
Now,
`V_s/V=(r/R)^(1/6)`
or, `V_s=0.956**0.85=0.8162\ m/s`
Also,
`s=(R/r)S=1/0.763**2.093**10^-3`
`=1/374.20`
All Chapters
View all Chapter and number of question available From each chapter from Sanitary-Engineering
Introduction
This chapter includes importance and objectives of waste management, sewage collection system, types of sewarage system, comparison of separate and combined system.
Quantity of Waste Water
The basic syllabus of this chapter includes Sources of sanitary sewages, factors affecting sanitory sewage, determination of quantity of sanitary sewages, variation in the quantity of sanitary sewage, determination of quantity of sanitary sewages, factors affecting storm sewages, time of concentration, time area graph and many more illustrative examples
Design of sewers Tutorial
This is the complete tutorial of Design of sewers Tutorial of sanitary engineering
Treatment of WasteWater
..
Similar Question
This Chapter Design-of-sewers-Tutorial consists of the following topics
Guest