Explain the effective length of a wall.
A load bearing masonry wall of a building is 20 cm thick and is laterally supported by RCC slabs at top and bottom, which are 12 cm thick each and the clear height between the slabs is 3.0 m. If the wall has an axial load of 71.5 KN/m at the base inclusive of self weight, What should be the crushing strength of bricks and grade of mortar for the wall. Wall is 4m long between cross walls and are of modular size. Assume that there are no opening in the wall within `H/8` of its junction with the load bearing wall under consideration. Assume that two ends of the wall are discontinuous and joints are not raked.
Solution:
Given,
Total load in wall `=71.5 (KN)/m`.
Thickness of wall`=20 cm`
Since the joints are not raked,
Actual thickness of wall `=20-1=19\ cm`
Again the wall is stiffened by cross walls. So,
`S_p/W_p=4/0.19=21.05>20`
Thus, the value of stiffening coefficient, `K_n` is `1`.
We know,
effective thickness = actual thickness * stiffening coefficient
or,`t_(ef)=t_(ac)*K_n`
or,`t_(ef)=0.19**1=0.19m`
Similarly,
Actual height,`H=3+0.12=3.12m`
and since the wall is restrained by RCC slabs at both top and bottom, the effective height is,
`H_(ef)=0.75H=0.75**3.12=2.34m`
Similarly,
Actual length, `L=4m`
Since the wall is discontinuous at both end and is supported by cross walls at both ends, we have the effective length as,
`L_(ef)=L=4m`
Now, we Know, the Slenderness ratio is,
`S.R=(H_(ef))/(t_(ef))or (L_(ef))....